Changes between Version 13 and Version 14 of WikiStart/CameraDoc
- Timestamp:
- Aug 13, 2020, 2:42:20 PM (5 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
WikiStart/CameraDoc
v13 v14 1 2 3 1 '''__Camera: CCD LOR #130__''' 4 2 5 * '''Working parameters at the 70 cm telescope ''' 6 || Pixel scale ||0.56 arcsec/px|| 7 || Field of View ||18.85 x 18.85 arcmin = 18.95 mm (without corrector)|| 8 || Installed at ||Cassegrain focal station|| 9 || Orientation || || 3 * '''Working parameters at the 70 cm telescope ''' 10 4 11 * '''Technical specifications ''' 12 ||Manufacturer || ||Loral / Lesser|| 5 || Pixel scale || 0.56 arcsec/px || 6 || Field of View || 18.85 x 18.85 arcmin = 18.95 mm (without corrector) || 7 || Installed at || Cassegrain focal station || 8 || Orientation || || 9 10 * '''Technical specifications ''' 11 12 ||Manufacturer || || Loral / Lesser || 13 13 ||Chip Manufacturer || || SITe || 14 14 ||Chip Model || ||n2k2eb BI || 15 ||Characteristics || || MPP, thinned, AR-coated||15 ||Characteristics || || MPP, thinned, AR-coated || 16 16 ||Operating temperature || || 163 K || 17 ||Dewar labelled || ||Dewar #23|| 17 ||Dewar labelled || || Dewar #23 || 18 18 19 - 19 ||Chip size (pixel) || || 2048 x 2048 || 20 ||Pixel size (μ) || || 15 x 15 || 21 ||Chip size (mm) || || 30.72 x 30.72 || 22 ||Measured QE|| ||See figure 'Efficiency'|| 20 21 ||Chip size (pixel) || || 2048 x 2048 || 22 ||Pixel size (μ) || || 15 x 15 || 23 ||Chip size (mm) || || 30.72 x 30.72 || 24 || Measured QE || || See figure 'Efficiency' || 25 23 26 - 27 24 28 || Reading time xx Hz ||~ 120 s (binning 1x1); ~30 s (binning 2x2) || 25 || Gain ||xx e^-/ADU ||26 || Read noise ||xx e^- rms||27 || Dark current ||xx e^-/pixel/hr (-163 ºC) ||28 || Linea lity ||xx||29 || Gain || xx e^-^ /ADU || 30 || Read noise ||xx e^-^ rms || 31 || Dark current ||xx e^-^ /pixel/hr (-163 ºC) || 32 || Linearity ||xx || 29 33 34 * '''Efficiency''' 35 * [http://www.eso.org/sci/php/optdet/instruments/CCDsystems/40/40.html] 30 36 31 * '''Efficiency''' 32 * [http://www.eso.org/sci/php/optdet/instruments/CCDsystems/40/40.html] 33 34 * '''Documentation ''' 35 * [https://svn.mpia.de/trac/gulli/king/attachment/wiki/WikiStart/CameraDoc/001-1.0-Mounting%20and%20dismounting%20procedure%20of%20the%20CCD%20LOR-130M.pdf Instructions to mount/dismount the CCD and cryostat from/to the telescope] 36 * [./Maintenance]: xxx, xxx 37 * [./Operations-manual Operations manual] 37 * '''Documentation ''' 38 * [https://svn.mpia.de/trac/gulli/king/attachment/wiki/WikiStart/CameraDoc/001-1.0-Mounting%20and%20dismounting%20procedure%20of%20the%20CCD%20LOR-130M.pdf Instructions to mount/dismount the CCD and cryostat from/to the telescope] 39 * [./Maintenance ./Maintenance]: xxx, xxx 40 * [./Operations-manual Operations manual]