    31'''__Camera: CCD LOR #130__'''
    42
    5 * '''Working parameters at the 70 cm telescope '''
    6 || Pixel scale   ||0.56 arcsec/px||
    7 || Field of View ||18.85 x 18.85 arcmin = 18.95 mm (without corrector)||
    8 || Installed at  ||Cassegrain focal station||
    9 || Orientation   || ||
     3 * '''Working parameters at the 70 cm telescope '''
    104
    11 * '''Technical specifications '''
    12 ||Manufacturer || ||Loral / Lesser||
     5|| Pixel scale || 0.56 arcsec/px ||
     6|| Field of View || 18.85 x 18.85 arcmin = 18.95 mm (without corrector) ||
     7|| Installed at || Cassegrain focal station ||
     8|| Orientation || ||
     9
     10 * '''Technical specifications '''
     11
     12||Manufacturer || || Loral / Lesser ||
    1313||Chip Manufacturer || || SITe ||
    1414||Chip Model || ||n2k2eb BI ||
    15 ||Characteristics || ||MPP, thinned, AR-coated||
     15||Characteristics || || MPP, thinned, AR-coated ||
    1616||Operating temperature || || 163 K ||
    17 ||Dewar labelled || ||Dewar #23||
     17||Dewar labelled || || Dewar #23 ||
     18
    1819-
    19 ||Chip size (pixel) || ||  2048 x 2048 ||
    20 ||Pixel size (μ) || ||  15 x 15 ||
    21 ||Chip size (mm) || ||  30.72 x 30.72 ||
    22 ||Measured QE|| ||See figure 'Efficiency'||
     20
     21||Chip size (pixel) || || 2048 x 2048 ||
     22||Pixel size (μ) || || 15 x 15 ||
     23||Chip size (mm) || || 30.72 x 30.72 ||
     24|| Measured QE || || See figure 'Efficiency' ||
     25
    2326-
     27
    2428|| Reading time xx Hz ||~ 120 s (binning 1x1); ~30 s (binning 2x2) ||
    25 || Gain               ||xx e^- /ADU ||
    26 || Read noise         ||xx e^- rms ||
    27 || Dark current       ||xx e^- /pixel/hr (-163 ºC) ||
    28 || Lineality         ||xx  ||
     29|| Gain || xx e^-^ /ADU ||
     30|| Read noise ||xx e^-^ rms ||
     31|| Dark current ||xx e^-^ /pixel/hr (-163 ºC) ||
     32|| Linearity ||xx ||
    2933
     34 * '''Efficiency'''
     35   * [http://www.eso.org/sci/php/optdet/instruments/CCDsystems/40/40.html]
    3036
    31 * '''Efficiency'''
    32  * [http://www.eso.org/sci/php/optdet/instruments/CCDsystems/40/40.html]
    33 
    34 * '''Documentation '''
    35  *  [https://svn.mpia.de/trac/gulli/king/attachment/wiki/WikiStart/CameraDoc/001-1.0-Mounting%20and%20dismounting%20procedure%20of%20the%20CCD%20LOR-130M.pdf  Instructions to mount/dismount the CCD and cryostat from/to the telescope]
    36  * [./Maintenance]: xxx, xxx
    37  * [./Operations-manual Operations manual]
     37 * '''Documentation '''
     38   * [https://svn.mpia.de/trac/gulli/king/attachment/wiki/WikiStart/CameraDoc/001-1.0-Mounting%20and%20dismounting%20procedure%20of%20the%20CCD%20LOR-130M.pdf Instructions to mount/dismount the CCD and cryostat from/to the telescope]
     39   * [./Maintenance ./Maintenance]: xxx, xxx
     40   * [./Operations-manual Operations manual]